Active energy measurement accuracy (large signal) | | 35A~100mA Input@ 1mohm sampling resistor | | 0.2 | | % |
Active energy measurement accuracy (small signal) | | 100mA~50mA Input@ 1mohm sampling resistor | | 0.4 | | % |
Active energy measurement accuracy (tiny signal) | | 50mA~10mA Input@ 1mohm sampling resistor | | 0.6 | | % |
RMS measurement accuracy(large signal) | | 35A~100mA Input@ 1mohm sampling resistor | | 0.2 | | % |
RMS measurement accuracy(small signal) | | 100mA~50mA Input@ 1mohm sampling resistor | | 2 | | % |
RMS measurement accuracy(tiny signal) | | 50mA~10mA Input@ 1mohm sampling resistor | | 6 | | % |
Fast RMS response time | 50Hz | Can be set to cycle/half cycle | 10 | | 40 | mS |
60Hz | 8.3 | | 33 | mS |
Zero-crossing signal output delay | | | | 571 | | uS |
Measurement error caused by phase angle between channels (capacitance) | PF08err | Phase advance 37 ゜ (PF=0.8) | | | 0.5 | % |
Measurement error caused by phase angle between channels (sensibility) | PF05err | Phase delay 60 ゜ (PF=0.5) | | | 0.5 | % |
AC power suppression (output frequency amplitude variation) | ACPSRR | IP/N=100mV | | | 0.1 | % |
DC power suppression (output frequency amplitude variation) | DCPSRR | VP/N=100mV | | | 0.1 | % |
Analog input level (current) | | Differential current input (peak) | | | 50 | mV |
Analog input level (voltage) | | Differential voltage input (peak) | | | 200 | mV |
Analog input impedance | | | | 370 | | kΩ |
SEL pull-down resistor | | SEL(pull-down) | | 56.9 | | kΩ |
Analog input bandwidth | | (-3dB) | | 3.5 | | kHz |
Internal voltage reference | Vref | | | 1.218 | | V |
Logic input high-level | | VDD=3.3V±5% | 2.6 | | | V |
Logic input low-level | | VDD=3.3V±5% | | | 0.8 | V |
Logic output high-level | | VDD=3.3V±5% IOH=5mA | VDD -0.5 | | | V |
Logic output low-level | | VDD=3.3V±5% IOL=5mA | | | 0.5 | V |