SSP7212

The SSP7212-ADJ series are highly precise, low noise, positive voltage LDO regulators manufactured using CMOS processes. The series achieves high ripple rejection and low dropout and consists of a standard voltage source, an error correction, current limiter and a phase compensation circuit plus a driver transistor. External output feedback, customers can easily get the required voltage . In order to make the load current does not exceed the current capacity of the output transistor , built-in over-current protection , over temperature protection and short circuit protection.
SSP1852

The SSP1852 is a high accuracy polyphase electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC62053-2x standard. The only analog circuitry used in the SSP1852 is in the analog-to-digital converters (ADCs) and reference circuit. All other signal processing (such as multi-plication, filtering, and summation) is carried out in the digital domain. This approach provides superior stability and accuracy over extremes in environmental conditions and over time.
The SSP1852 supplies average real power information on the low frequency outputs, F1 and F2. These logic outputs may be used to directly drive an electromechanical counter or to interface with an MCU. The CF logic output gives instanta-neous real power information. This output is intended to be used for calibration purposes.
The SSP1852 includes a power supply monitoring circuit on the VDD pin. The SSP1852 remains inactive until the supply voltage on VDD reaches 4 V. If the supply falls below 4 V, no pulses are issued on F1, F2, and CF. Internal phase matching circuitry ensures that the voltage and current channels are phase matched. An internal no load threshold ensures the part does not exhibit any creep when there is no load.
The SSP1852 is available in a 24-lead SOIC package.
SSP1922

SSP1922 is a high accurate time measurement (TDC) circuit. SSP1922 integrates analog comparator, analog switch, Schmidt flip-flop and other internal devices, thus greatly simplifying the peripheral circuit. At the same time, the first wave detection function is added inside, so that the anti-interference ability is greatly improved. The programmable offset range of the comparator is increased to ±35mV, the sampling accuracy can be improved.Measuring the relative pulse width of the first wave gives the user an indication of the strength of the received signal. Through this hint, we can judge the abnormal detection of ultrasonic transducer, the increase of wall covering, the presence of bubbles in water and so on. The Start-TOF-Restart command can complete a measurement of ultrasonic time difference (upstream and downstream) and data reading, so as to greatly reduce the software operation and power consumption. Compatible with TDC – GP22.